C-Band Up

Home Up Ku-Band Up C-Band Block Up C-Band Up L-Band Up

 

Click to zoom in...

MP-9260 C-Band Up Converter

MP-9260 C-Band Upconverter

bullet

PDF file get free pdf reader

bullet

Input

bullet

Output

bullet

Transfer

bullet

Reference

bullet

Front Panel

bullet

Rear Panel

bullet

General

bullet

Miscellaneous

Click to zoom in...

Top View
More Photos


Input Characteristics
Frequency Range 70 20 MHz
  140 40 MHz (optional)
Impedance 75W (50W optional)
Return Loss > 26 dB

Output Characteristics 
Frequency Range 5850 to 6650 MHz
Impedance 50W
Return Loss > 23 dB

Transfer Characteristics 
Conversion Gain 30 dB
Gain Flatness 0.5 dB (5850 to 6650 MHz)
Amplitude Flatness 0.25 dB (70 20 MHz)
Amplitude Ripple 0.5 dB p-p (70 20 MHz)
Attenuator Range  0 to 30 dB (continuous)
Attenuator Resolution  0.1 db
Gain Stability  
  Over 24hrs at constant temp  0.25 dB
  0 C to +50 C 0.35 dB
Phase Noise (SSB)  
  100 Hz 63 dBc 
  1 kHz 75 dBc
  10 kHz 85 dBc
  100 kHz 97 dBc
Third Order Intermodulation Distortion
  Output (full gain) -40 dBc @ 0 dBm output per carrier
  Output 1dB Compression +10 dBm @ 30 dB Gain
Group Delay  
  Linear 0.06 nS / MHz
  Parabolic 0.015 nS / (MHz)2
Spurious  
  Carrier Dependent -70 dBc at full gain
  Carrier Independent -70 dBm at full gain
Image Rejection  
  1st Mixer -75 dBc (out of band)
  2nd Mixer -75 dBc (out of band)
  3rd Mixer -80 dBc (in band)
Mute -80 dBc

Reference 
Frequency 10 MHz
Frequency Stability 5 x 10-9 from 0 to 50 C
Frequency Aging: 5 x 10-10 per day
  1 x 10-7 per year
Warmup 1 x 10-7 after 2.5 min @ 25C

Front Panel 
Display LCD 2 x 40 Character (Backlit)
Data Entry Keyboard
Indicators Power, Alarm, Remote, Ext Ref
Monitor Points IF (BNC Female)
LO SMA (Female)

Rear Panel 
RF Output SMA Female (type N optional)
RF Input BNC Female (75W)
Ext Reference 5 or 10 MHz BNC Female
Remote Control:  
  RS232 9-pin D Male
  RS485 9-pin D Male
Summary Alarm 9-pin D Female (Form-C Relay)

General 
Size 13.5D x 19W x 1.75H
Weight 13 lbs
Power Consumption 30 Watts max
Voltage 100-240 V AC 50/60Hz
Temperature 0 to 50C

Miscellaneous 
Remote Control:  
    All Front Panel Functions and Full Status Reporting
External Reference:
5 or 10 MHz external reference with auto detection and locking of internal reference with a lock range of 5 x 10-7.

 

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone
Product

 

Hit Counter

Home ] Up ] Ku-Band Up ] C-Band Block Up ] [ C-Band Up ] L-Band Up ]

Send mail to webmaster@microphaseinc.com with questions or comments about this web site.
Copyright 2000 Micro Phase Communications, Inc